Siemens PLC control system PLC
Siemens control system providing the operator with access to all DRYAIR desiccant dehumidifier functions via a single interactive touch-screen. It is a reliable system for precisely controlling dehumidifier reactivation energy and the multiple cooling coils that provide low dew points and comfortable dry room temperature control.
Siemens S7 control system can be modified or expanded by modifying engineering software as additional ZCH series systems are added. The engineering software can provide a graphical presentation of the ZCH Series system to access and track all dry room variables including room temperature, coil temperatures, compressor discharge temperature, and multiple point dew points.
Optional updated PLC is available
Optional: With a GPRS remote control SIM card installed, it will enable DRYAIR worldwide service access to our dry rooms; online consultation, system service and trouble shooting from our headquarters can be provided to help reduce maintenance costs and insure that systems always perform at optimal conditions.
Siemens PLC control system PLC
Siemens control system providing the operator with access to all DRYAIR desiccant dehumidifier functions via a single interactive touch-screen. It is a reliable system for precisely controlling dehumidifier reactivation energy and the multiple cooling coils that provide low dew points and comfortable dry room temperature control.
Siemens S7 control system can be modified or expanded by modifying engineering software as additional ZCH series systems are added. The engineering software can provide a graphical presentation of the ZCH Series system to access and track all dry room variables including room temperature, coil temperatures, compressor discharge temperature, and multiple point dew points.
Optional updated PLC is available
Optional: With a GPRS remote control SIM card installed, it will enable DRYAIR worldwide service access to our dry rooms; online consultation, system service and trouble shooting from our headquarters can be provided to help reduce maintenance costs and insure that systems always perform at optimal conditions.

Chilled water systems include both supply and return piping in a closed circuit, Chilled Water systems work by pumping chilled water throughout the cooling coils and chiller. The air which is cooled by the coils is then transferred to humidity contro...


This system is designed to recycle NMP from the lithium-ion secondary battery electrodes manufacturing process. The hot solvent laden air from the ovens is drawn into DRYAIR’s NMP Recovery System where the NMP is recovered by a combination of condens...

SPEC SHEET-VOC abatement system .pdf

DRY AIR FLOW:2,000-35,000CMH Humidity Control:5%RH/2%RH/below 1% Supply Air Dew Point:-70℃ Application: Lithium Battery

DRY AIR FLOW:2,000-60,000CMH Humidity Control:10%RH-40%RH Appicaltion:Pharmaceutical, Food,Glass,Chemical

DRY AIR FLOW:2,000-20,000CMH REACTIVATION HEATING:60℃

SPEC SHEET ZCS-SERIES .pdf


SPEC SHEET ZCLY-SERIES .pdf

SPEC SHEET ZCLY-SERIES .pdf

SPEC SHEET ZC series .pdf


SPEC SHEET-ZCR series .pdf

SPEC SHEET DJDD.pdf

SPEC SHEET DJ series.pdf

SPEC SHEET DJ series.pdf

SPEC SHEET DJ series.pdf

DRY ROOM DESIGN,FABRICATION&INSTALLATION CLEAN AND DRY ROOM · Modular Wall System · Vapor-tight panels with metal facing on both sides · Fire rated panels available · Airlock(optional MAL AND PAL),Steel door,LED light · 0.07% – 45% relative humidity...

AIR DISTRIBUTION SYSTEM The air from Dehumidifier Unit is ducted into metal perforated air distribution modules located in the dry room ceiling which deliver air uniformly downwards throughout all of the work space. Air shall return to the air handl...

Chilled water systems include both supply and return piping in a closed circuit, Chilled Water systems work by pumping chilled water throughout the cooling coils and chiller. The air which is cooled by the coils is then transferred to humidity contro...


This system is designed to recycle NMP from the lithium-ion secondary battery electrodes manufacturing process. The hot solvent laden air from the ovens is drawn into DRYAIR’s NMP Recovery System where the NMP is recovered by a combination of condens...

SPEC SHEET-VOC abatement system .pdf

DRY AIR FLOW:2,000-35,000CMH Humidity Control:5%RH/2%RH/below 1% Supply Air Dew Point:-70℃ Application: Lithium Battery

DRY AIR FLOW:2,000-60,000CMH Humidity Control:10%RH-40%RH Appicaltion:Pharmaceutical, Food,Glass,Chemical

DRY AIR FLOW:2,000-20,000CMH REACTIVATION HEATING:60℃

SPEC SHEET ZCS-SERIES .pdf